Milwaukee CMM Calibration and Repair

Primary Service

CMM Calibration and Repair

Request a quote for verification or repair.

  • Work performed under ISO/IEC 17025:2017
  • Serving Wisconsin and the Greater Midwest
  • As-found data recorded before adjustment
  • Certificate states method, conditions and uncertainty

Request a quotation

Quotations are returned in writing by email.

What a verification visit covers

Performance verification confirms a machine still meets its specification. The visit sequence runs scales and reader heads, air bearings, geometry, then the length measurement error test under ISO 10360-2 and probing error under ISO 10360-5.

Large-envelope bridge and gantry machines common to machinery builders carry long-bed travel, which changes fixturing and artifact handling versus a small production CMM. Where a fourth-axis rotary table is fitted, it is tested separately under ISO 10360-3:2000, using two test spheres at a specified height difference and radius.

Sequence and artifacts

Each stage uses a specific artifact and detects a specific class of error, in the order a technician actually works the machine.

  1. Scales and reader heads

    X, Y and Z scales are cleaned and inspected; reader heads are checked and adjusted to proper output.

  2. Geometry

    Straightness, linearity and squareness in the XY, ZX and ZY planes, measured with laser interferometry or indirect multilateration.

  3. Length measurement error

    Five calibrated lengths, three repeats, seven positions: 105 measurements against E0,MPE under ISO 10360-2.

  4. Probing error

    A 25-point PFTU test on a dedicated calibrated sphere per ISO 10360-5:2020, separate from the probe's reference sphere.

  5. Volumetric compensation

    The controller's error-compensation map is updated where the controller allows it; some OEM controllers lock this map.

On a verification visit

  1. Soak

    Artifacts and machine are allowed to reach ambient before testing starts.

  2. As-found

    Geometry and length error are measured before any adjustment is made.

  3. Adjustment

    Geometric adjustment and compensation update proceed where the as-found result allows.

  4. As-left

    Verification is repeated and the certificate is issued with before-and-after results.

Why Milwaukee CMM Calibration and Repair

  1. Repair on the same visit

    Probe, scale, air bearing and drive repair can be addressed when a verification finding calls for it.

  2. Large-bed handling

    Long-travel bridge and gantry machines and their test lengths are fixtured for their actual envelope, not a shop default.

  3. Crash recovery and relocation

    Re-verification follows any crash or relocation, before the machine returns to production use.

Coverage across Wisconsin and the Greater Midwest

Service area covers Milwaukee and the surrounding Wisconsin metros listed on this site. Machines outside that radius should request a quote to confirm scheduling.

Discuss CMM Calibration and Repair Requirements

Send the machine make, model and axis travel.

Quotations are returned in writing by email.

Request a Quote + CertEmail Us