Quality System

Quality System & Standards


The standards, traceability and management arrangements that govern the work described on this site.

StandardISO/IEC 17025:2017
Disciplines3

Overview

Calibration is performed by laboratories accredited to ISO/IEC 17025:2017. Each request is checked against the performing laboratory's published scope of accreditation before it is quoted, and accredited and non-accredited items are identified separately on both the quotation and the resulting certificate.

Standards Referenced

Work described on this site is performed under ISO/IEC 17025:2017.

Where accreditation appears on this site it refers to the performing laboratory's own accreditation, limited to the measurements in its published scope. Requests that fall outside that scope are accepted where the capability exists, reported as non-accredited, and identified as such on the certificate. Every accreditation named here belongs to the laboratory performing the measurement.

Metrological Traceability

Measurements are traceable to the SI through NIST. Certificates state the reference standards used, the method applied, and the reported measurement uncertainty, including the coverage factor. Where a statement of conformity is issued, the decision rule applied is stated on the certificate, consistent with ISO/IEC 17025:2017 and ISO 14253-1. Reported uncertainty for a given range is checked against the performing laboratory's calibration and measurement capability before the certificate is issued.

Each measurement carries its own traceability record rather than a blanket statement: the certificate identifies the reference used, that reference's calibration status, and the documented chain linking it to the SI unit. If a reference is later found out of tolerance, everything measured against it since its last calibration is reviewed and the affected customers are told.

Equipment and Maintenance

Equipment categories supported include bridge, gantry and cantilever coordinate measuring machines, portable articulated arms, granite surface plates, gauge blocks, and ring and plug gauges. Where adjustment or repair is performed, results before and after are recorded on the certificate. Out-of-tolerance findings are reported with as-found data prior to correction, allowing a reverse-traceability impact assessment against the last passing calibration. Records, asset identifiers and due-date recall notices are retained for retrieval at audit.

References are uniquely identified, environmentally controlled, and recalibrated to a defined schedule that drift data can shorten but not quietly extend. Damaged, overloaded or questionable equipment is removed from service and labelled until it has been verified and formally released back into use.

Management System

The work sits inside a documented management system:

  • 01

    Controlled documents

    Procedures carry issue and revision status.

  • 02

    Retained records

    Retained for a defined period and retrievable against a certificate number.

  • 03

    Audit and review

    Internal audit and management review run on a schedule.

  • 04

    Corrective action

    Nonconforming work and improvement actions are tracked to closure, and their effectiveness is checked afterwards.

Impartiality and Complaints

Where impartiality could be compromised the risk is identified and controlled, and the reported result follows the measurement rather than the commercial interest. Complaints and appeals are a formal input to the system — the process, including the response commitment, is set out on the complaints policy page. How results should and should not be read is covered on the disclaimer page.

Need supplier-approval documentation?

Scope, method statements and traceability detail are supplied with the quotation.

A written quotation is sent back by email.